PV Peripheral Pump Range General Product Description
PERFORMANCE RANGE
Flow rate up to 10 L/min (0.6 m³/hr)
Dynamic head up to 55m
OPERATING LIMITS
Suction lift up to 8m
Fluid temperature up to + 90°C
Maximum ambient temperature + 40°C
PUMP INSTALLATION AND APPLICATIONS
These pumps are suitable for handling clean water not containing
abrasive particles, and fluids which are
not chemically aggressive to the pump components.
THE HYDRAULIC PERFORMANCE OF THIS STURDY AND COMPACT BRASS PUMP
MAKES THEM IDEALLY SUITED FOR TRANSFERRING LIQUIDS IN THE MECHANICAL
PROCESSING SECTOR, FOR CONTROLLING THE TEMPERATURE OF MOULDS, COOLING,
CONDITIONING AND FOR BEVERAGE DISPENSING MACHINES.
This particularly compact pump reaches high performances from very
low motor powers and is therefore suitable for cooling welding torches.
These pumps should be installed in a covered area, protected against
the weather.
PERFORMANCE
The PV pump is designed to suit a wide range of applications, with
features including:
- Anti-seize, brass pump head suitable for industrial use.
- High heads achieved from low motor powers.
- Small variations in delivery rates in the event of changes
in the pressure demand;
- High tolerance to entrained air in the pumped liquid
STRUCTURAL CHARACTERISTICS
- Brass PUMP BODY, with UNI ISO 228/1 1/4" threaded
suction and delivery ports
- Aluminum MOTOR BRACKET with brass insert (patented).
- BRASS IMPELLER, with radial peripheral blades, floating
on the shaft
- EN 10088-3-1.4104 stainless steel MOTOR SHAFT
- MECHANICAL SEAL: ceramic - carbon - EPDM
MOTOR: pumps are coupled directly to an asynchronous,
high efficiency PEDROLLO induction motor, which is quiet running,
closed and externally ventilated, with <IM B3> structural
shape, suitable for continuous duty. INSULATION class F.
A thermal cutout device (motor protector) is incorporated
in single phase motors.
Three phase motors require an adequate external motor protector
complying with current standards
- PROTECTION IP 44.
- CONSTRUCTION AND SAFETY STANDARDS complies with EN60034-1,
IEC 34-1, CEI 2-3
- REGISTERED MODEL
*Installations must comply to Water Bye-laws in the UK.
PERFORMANCE CURVE

PERFORMANCE DATA
PRODUCT DIMENSIONS
|